Stainless Steel Chamber Manufacturing Process

The stainless steel chamber is the main body component of a UV sterilizer, and its manufacturing quality directly affects the pressure-bearing performance, hygienic performance and appearance of the equipment. Longkang uses CNC machining and argon-arc welding processes to ensure chamber quality. This article explains the stainless steel chamber manufacturing process in detail.
1. Chamber structure
The chamber of a UV sterilizer mainly consists of the following parts:
- Cylinder: cylindrical, the water flow channel
- End caps: covers at both ends, holding the lamp seats
- Inlet and outlet flanges: water in and out
- Lamp seat holes: for mounting quartz sleeves and lamps
- Drain port: drainage at the bottom
- Vent port: air release at the top
- Supports: for mounting and fixing
2. Material selection
2.1 Material grade
- Standard: 304 stainless steel (06Cr19Ni10)
- High chloride-ion water: 316L stainless steel (022Cr17Ni12Mo2)
- Food grade: food-grade 304 or 316L
- Standard: GB/T 20878 stainless steel grades
2.2 Plate thickness
- Small chamber (below DN50): 1.5 mm
- Medium chamber (DN50 to DN150): 2.0 mm
- Large chamber (above DN150): 2.5 to 3.0 mm
- Wall thickness calculated according to pressure requirements
2.3 Material standards
- Cold-rolled stainless steel sheet
- Surface 2B or BA
- Tolerance: ±0.1 mm
- Material certificate supplied with the goods
3. Cutting process
3.1 Cylinder cutting
- Cut according to the developed dimensions
- Developed length = π × (outer diameter − wall thickness)
- CNC shearing machine or laser cutting
- Dimensional accuracy ±0.5 mm
- Diagonal difference ≤1 mm
3.2 End cap cutting
- Circular end caps: laser cutting or punching machine
- Diameter tolerance ±0.5 mm
- Flatness ≤0.5 mm
3.3 Flange cutting
- Standard flanges: purchased finished products
- Non-standard flanges: laser cutting
- Flange thickness according to the standard
3.4 Deburring
- Remove burrs after cutting
- Chamfer C0.5 to C1
- Prevent scratching
4. Rolling process
4.1 Plate rolling machine
- Three-roll or four-roll plate rolling machine
- Roll diameter selected according to plate thickness
- Rolling diameter adjustable
4.2 Rolling process
- Feed the plate into the rolling machine
- Apply pressure gradually to roll into shape
- Roll repeatedly until roundness is qualified
- Align the butt seam
4.3 Quality requirements
- Diameter tolerance ±1 mm
- Roundness ≤2 mm
- Butt seam gap ≤1 mm
- Misalignment ≤0.5 mm
- No indentations or scratches on the surface
5. Welding process
5.1 Welding method
- Argon-arc welding (TIG): tungsten inert gas shielded welding
- Welding wire: stainless steel wire of the same material
- Shielding gas: 99.99% argon
- Welding current: adjusted according to plate thickness
5.2 Longitudinal seam welding
- Weld the longitudinal seam of the cylinder
- Single-side welding with double-side forming
- Welding parameters: current 80 to 120 A, voltage 10 to 14 V
- Weld reinforcement 0.5 to 1.5 mm
- Weld width 3 to 5 mm
5.3 Circumferential seam welding
- Weld the circumferential seam between end cap and cylinder
- Used together with a rotating worktable
- Continuous welding
- Uniform weld seam
5.4 Flange welding
- Weld inlet and outlet flanges to the cylinder
- Fillet weld
- Leg height = wall thickness
- Continuous weld seam, no arc interruption
5.5 Lamp seat welding
- Weld the lamp seat to the chamber
- Fillet weld
- Seal welding to ensure no water leakage
- Cleaning after welding
5.6 Welding quality requirements
- Weld surface smooth, with no pores, cracks or slag inclusions
- Weld reinforcement 0.5 to 1.5 mm
- No undercut or incomplete penetration
- Remove slag and oxide discoloration after welding
- Pickling and passivation of weld seams (optional)
6. Polishing process
6.1 Inner wall polishing
- Mechanical polishing: grinding wheel plus cloth wheel
- Or electrolytic polishing
- Roughness Ra≤0.8 µm (sanitary grade)
- Bright surface, no scratches
- Reduce microbial adhesion
6.2 Outer wall treatment
- Brushed finish: 180# to 240# abrasive belt
- Or matte finish
- Uniform surface
- No obvious scratches
6.3 Weld seam polishing
- Grind weld reinforcement smooth
- Smooth transition with the base material
- Inner wall welds must be polished
- Outer wall welds may be left as-is or polished
7. Machining process
7.1 Lamp seat hole machining
- CNC lathe or milling machine
- Hole position accuracy ±0.5 mm
- Chamfer the hole mouth
- Smooth hole wall
7.2 Flange machining
- Standard flanges purchased
- Non-standard flanges machined by CNC
- Machining of the sealing surface
- Drilling of bolt holes
7.3 Thread machining
- Threads for small-diameter connections
- Pipe thread (GB/T 7306)
- Smooth threads, no broken threads
8. Hydrostatic test
8.1 Test equipment
- Hydrostatic test machine
- Pressure gauge (accuracy class 1.6)
- Pressure test pump
8.2 Test parameters
- Test pressure: 1.5 times the rated pressure
- Pressure holding time: 10 to 30 minutes
- Medium: clean water
8.3 Test procedure
- Seal all openings (leave one water inlet)
- Fill with water and expel all air
- Slowly pressurize to the test pressure
- Hold pressure for 10 to 30 minutes
- Inspect all weld seams and seals
- No leakage and no deformation means qualified
- Release pressure and drain water
8.4 Records
- Test record for each unit
- Test pressure, holding time and result
- Signed by the test operator
- Archived
9. Chamber cleaning
9.1 Degreasing
- Degrease with alkaline cleaner
- Remove machining oils and grease
- Rinse with clean water
9.2 Pickling and passivation
- Pickling with a nitric acid + hydrofluoric acid mixture
- Remove oxide scale and weld spots
- Passivation treatment to improve corrosion resistance
- Rinse with clean water until neutral
9.3 Pure water rinsing
- Final rinse with pure water
- Remove chloride ions
- Drying
9.4 Hygiene testing
- Cleanliness testing of the inner wall
- No oil stains, no impurities
- Meets food-grade hygiene requirements
10. Longkang chamber manufacturing advantages
- CNC cutting for accurate dimensions
- Standardized rolling for good roundness
- Argon-arc welding for neat weld seams
- Inner wall polishing, sanitary grade
- Hydrostatic test on every unit to ensure pressure bearing
- Pickling and passivation for corrosion resistance
- Pure water cleaning for hygiene
- Full-process quality control
For selection support and guidance on stainless steel chamber manufacturing, contact Longkang.