Quartz Sleeve Transmittance Parameters for Open-Channel UV Disinfection Systems: A Detailed Explanation

Quartz sleeves in an open-channel UV disinfection module with automatic mechanical cleaning brushes
Maintaining 254 nm sleeve transmittance is central to reliable open-channel UV disinfection.

The quartz sleeve is a critical component of an open-channel UV disinfection system, and its transmittance directly affects the effective UV dose and the disinfection result. In wastewater applications the sleeve also has to withstand scaling, corrosion and abrasion, so its transmittance declines with operating time. This article explains the transmittance parameters of quartz sleeves, the factors that influence them, the methods used to measure them, and the key maintenance practices, described in terms of actual field conditions.

1. Basic Concepts of Quartz Sleeve Transmittance

1.1 Definition

Transmittance (T) of a quartz sleeve is the ratio of the UV energy at a specific wavelength that passes through the sleeve to the incident energy, normally expressed as a percentage:

  • Transmittance (T) = transmitted energy (I) ÷ incident energy (I0) × 100%
  • UV disinfection systems are concerned with transmittance at 254 nm (the germicidal peak wavelength)

1.2 Why Transmittance Matters

  • UV light must pass through the sleeve before it can reach the microorganisms in the water
  • Higher transmittance means more effective UV output and better disinfection performance
  • For every 5% drop in transmittance, the effective dose falls by roughly 5%
  • Transmittance is the single most important performance parameter of the sleeve
  • Scaling on the sleeve significantly reduces transmittance and is the most common problem in operation

1.3 Standard Requirements

  • HJ 2029 (urban wastewater UV disinfection engineering code): 254 nm transmittance ≥ 90%
  • GB/T 19837 (UV disinfection equipment for municipal water supply and drainage): 254 nm transmittance ≥ 90%
  • Longkang sleeves: 254 nm transmittance ≥ 92% (above the standard requirement)
  • Transmittance uniformity over the full sleeve length: ±2%

2. Factors Affecting Quartz Sleeve Transmittance

2.1 Material Purity

  • The purity of the quartz glass (SiO2 content) directly affects transmittance
  • Impurities such as iron, aluminium, calcium and hydroxyl (OH–) absorb UV light
  • JGS2 UV-grade optical quartz glass: SiO2 ≥ 99.99%, 254 nm transmittance ≥ 90%
  • JGS1 far-UV optical quartz glass: SiO2 ≥ 99.999%, higher transmittance (≥ 93%), but it transmits 185 nm and generates ozone
  • Ordinary fused quartz: SiO2 ≥ 99%, transmittance 80%–85%, unsuitable for disinfection systems
  • JGS2 UV-grade optical quartz glass must therefore be selected

2.2 Hydroxyl (OH–) Content

  • Hydroxyl groups (OH–) in quartz glass absorb UV light near 254 nm
  • The higher the hydroxyl content, the lower the transmittance
  • Synthetic quartz (low hydroxyl, <10 ppm) has high transmittance
  • Fused quartz (high hydroxyl, 100–300 ppm) has low transmittance
  • JGS2 is produced by a synthetic process and has a low hydroxyl content

2.3 Wall Thickness

  • As UV light passes through the sleeve, part of it is absorbed inside the quartz material
  • A thicker wall means a longer optical path, more absorption and lower transmittance
  • 1.5 mm wall: transmittance approx. 92%–93%
  • 2.0 mm wall: transmittance approx. 90%–91%
  • 2.5 mm wall: transmittance approx. 88%–89%
  • Open-channel systems work at low pressure, so a thin 1.5 mm wall can be chosen (higher transmittance)
  • Pressurised in-pipe systems work at higher pressure and need a 2.0–2.5 mm wall (greater strength)

2.4 Surface Quality

  • Surface roughness affects transmittance (a rough surface scatters UV light)
  • Polished surface (Ra ≤ 0.8 µm): high transmittance, little scattering
  • Unpolished surface: low transmittance, more scattering
  • Surface scratches and pits cause local scattering and reduce transmittance
  • Both the inner and the outer surfaces should be polished

2.5 Bubbles and Stones

  • Bubbles and stones (solid impurity particles) in quartz glass scatter and absorb UV light
  • Bubbles larger than 0.5 mm in diameter significantly affect transmittance
  • Stones permanently reduce transmittance (they cannot be restored by cleaning)
  • High-quality quartz glass should contain no bubbles or stones visible to the naked eye
  • Every sleeve should undergo a visual inspection before leaving the factory

2.6 Temperature

  • The transmittance of quartz glass varies slightly with temperature
  • As temperature rises, transmittance drops slightly (thermal expansion and thermally activated absorption)
  • Within the operating temperature range (0–200 °C), the change is <1%
  • Open-channel UV systems run at low temperatures (40–120 °C), so the temperature effect is negligible

2.7 Scaling on the Outer Sleeve Surface (the Dominant Operating Factor)

  • Minerals such as calcium, magnesium, iron and manganese in wastewater deposit on the outer sleeve surface
  • The scale layer absorbs and scatters UV light, significantly reducing transmittance
  • 0.1 mm of scale: transmittance reduced by 20%–30%
  • 0.5 mm of scale: transmittance reduced by more than 50%
  • Wastewater with high iron content: iron oxides deposit, and scaling is faster and more severe
  • Hard water (high calcium and magnesium): calcium carbonate deposits, with severe scaling
  • This is the main reason transmittance declines during operation
  • An automatic cleaning system must be provided, together with regular cleaning

2.8 Contamination of the Inner Sleeve Surface

  • Under normal conditions the inside of the sleeve is dry (air fills the gap between the sleeve and the lamp)
  • If the seal fails and water leaks into the sleeve, scale forms on the inside
  • Internal scale cannot be removed by external cleaning
  • The sleeve must be replaced
  • Seal quality is therefore critical

2.9 Biological Growth (Biofouling)

  • Microorganisms in wastewater may attach and grow on the sleeve surface (biofilm)
  • A biofilm blocks UV light
  • However, UV intensity close to the lamp is high, so biofilm does not readily develop there
  • The lamp ends (where intensity is lower) may see biological attachment
  • Automatic cleaning removes biofilm effectively

2.10 Abrasion

  • Suspended solids (sand particles) in wastewater scour the sleeve surface over time
  • The surface becomes rough, scattering increases and transmittance falls
  • Wastewater with high SS causes more severe abrasion
  • Abrasion is irreversible (it cannot be recovered)
  • Severely abraded sleeves must be replaced

3. Methods for Measuring Quartz Sleeve Transmittance

3.1 Factory Testing (Every Sleeve Must Be Tested)

Test equipment:

  • UV spectrophotometer (measures transmittance at 254 nm)
  • Standard cuvette or a dedicated measurement fixture

Test procedure:

  1. Clean the sleeve surface with anhydrous ethanol
  2. Place the sleeve in the measurement fixture (make sure the optical path passes perpendicularly through the sleeve wall)
  3. Use air as the reference (100% transmittance)
  4. Measure the transmittance at a wavelength of 254 nm
  5. Measure at several positions on the sleeve (both ends and the middle) and take the average
  6. Record the test result
  7. Transmittance ≥ 90% (Longkang ≥ 92%) is accepted as conforming

Test standard:

  • Every sleeve must be tested
  • Test records must be archived
  • Non-conforming sleeves must not be used

3.2 In-Service Monitoring (Indirect Monitoring)

Sleeve transmittance cannot be measured directly during operation, but it can be judged indirectly from the following parameters:

(1) UV intensity monitoring

  • Install a UV intensity monitor in the disinfection channel
  • Monitor UV intensity in real time
  • Record the initial intensity with a new lamp and a clean sleeve
  • A continuous drop in intensity during operation may indicate sleeve scaling
  • If intensity recovers after cleaning, scaling is the cause
  • If intensity remains low after cleaning, the cause may be lamp aging or sleeve abrasion

(2) Cumulative lamp operating hours

  • Log the cumulative operating hours of the lamps
  • Near the end of lamp life (8,000–12,000 h), the output decays
  • A drop in intensity may be caused by lamp aging rather than by a sleeve problem
  • If intensity recovers after the lamps are replaced, the lamps were the cause

(3) Intensity comparison before and after cleaning

  • Record UV intensity before and after automatic cleaning
  • A clear recovery after cleaning (>10%) indicates severe scaling
  • No change in intensity after cleaning means scaling is not the problem
  • The cleaning frequency can be adjusted according to the cleaning effect

3.3 Manual Inspection (Periodic Sampling)

(1) Visual inspection

  • Lift the module out and visually inspect the sleeve surface
  • Check for scale, discolouration, scratches and cracks
  • Severe scaling appears as white or yellow deposits on the surface
  • High iron content produces reddish-brown deposits

(2) Transmittance sampling

  • Periodically (once a year) take a sample of one or two sleeves
  • Send them to a laboratory to measure 254 nm transmittance with a UV spectrophotometer
  • Compare with the initial transmittance to assess the degree of decay
  • If transmittance has fallen by more than 10% (after cleaning), consider replacing the sleeve

(3) Biodosimetric validation

  • Important projects can carry out biodosimetric validation
  • Use indicator microorganisms to verify the actual disinfection effect
  • Assess the effective dose and sleeve transmittance indirectly

4. Transmittance Decay Patterns Under Different Water Qualities

4.1 High-Quality Effluent (UVT > 75%, SS < 10 mg/L)

  • Effluent after advanced treatment (after filtration)
  • Low mineral content, slow scaling
  • Automatic cleaning keeps transmittance stable
  • Manual cleaning interval: 6–12 months
  • Sleeve service life: more than 5 years

4.2 Average Effluent (UVT 65%–75%, SS 10–20 mg/L)

  • Secondary treatment effluent (after the secondary clarifier)
  • Moderate mineral content, medium scaling rate
  • Automatic cleaning 1–2 times per day
  • Manual cleaning interval: 3–6 months
  • Sleeve service life: 3–5 years

4.3 Poor Effluent (UVT 55%–65%, SS 20–30 mg/L)

  • Secondary treatment effluent (with large fluctuations in water quality)
  • High mineral content, relatively fast scaling
  • Automatic cleaning 2–4 times per day
  • Manual cleaning interval: 1–3 months
  • Sleeve service life: 2–3 years

4.4 High-Iron Water (Fe > 0.5 mg/L)

  • Iron oxides deposit rapidly on the sleeve surface
  • Extremely fast scaling (visible scale can form within a few days)
  • Reddish-brown deposits that are difficult to clean
  • Automatic cleaning 4 or more times per day
  • Manual cleaning interval: 2–4 weeks
  • Pre-treatment for iron removal is recommended
  • Sleeve service life: 1–2 years

4.5 High-Hardness Water (CaCO3 > 300 mg/L)

  • Calcium carbonate deposits on the sleeve surface (especially at higher temperatures)
  • White, hard scale that is not easy to clean
  • Automatic cleaning is of limited effect
  • Regular chemical cleaning (mild acid cleaning) is required
  • Manual cleaning interval: 1–2 months
  • Sleeve service life: 2–3 years

5. Measures to Maintain Sleeve Transmittance

5.1 Automatic Cleaning System (Mandatory)

  • A motorised mechanical cleaner that travels back and forth along the sleeve
  • Food-grade silicone cleaning brushes that do not scratch the sleeve
  • Adjustable cleaning frequency (1–4 times per day)
  • Cleaning can be triggered automatically according to UV intensity
  • Automatic cleaning keeps transmittance stable (decay <5%)
  • This is the primary measure for maintaining transmittance

5.2 Periodic Manual Cleaning

  • Carry out manual cleaning at intervals set by the water quality (1–12 months)
  • Lift the module out and wipe the sleeve with a soft cloth or sponge and a dedicated cleaning agent
  • Do not use steel wool or stiff brushes (they scratch the surface)
  • Do not use hydrofluoric acid (it corrodes quartz)
  • Rinse thoroughly with clean water after cleaning
  • For the detailed method, see Article 38 of this series

5.3 Online Chemical Cleaning (Optional, for Severe Scaling Water)

  • Add a mild acid (citric acid or acetic acid) to the cleaning system
  • Perform chemical cleaning periodically (once per month)
  • Dissolves mineral scale
  • Rinse with clean water after cleaning
  • Suitable for high-hardness and high-iron water
  • Pay attention to chemical safety and wastewater handling

5.4 Pre-Treatment to Improve Water Quality

  • Install filtration before disinfection (deep-bed filters, V-type filters, membrane filtration)
  • Reduce SS and turbidity to limit sleeve abrasion and scaling
  • Iron and manganese removal pre-treatment (for high-iron water)
  • Softening pre-treatment (for high-hardness water)
  • Improving water quality significantly extends the cleaning interval and sleeve life

5.5 Anti-Scaling Coating (Optional)

  • Apply a nano anti-scaling coating to the outer sleeve surface
  • Coating thickness below 100 nm, with no effect on transmittance
  • Reduces mineral attachment
  • Doubles the cleaning interval
  • Suitable for high-hardness and high-iron water
  • Coating service life approx. 2–3 years

5.6 Appropriate Lamp Power and Temperature

  • Medium-pressure lamps have a high wall temperature (80–120 °C), which promotes mineral deposition (similar to scale in a kettle)
  • Low-pressure lamps have a low wall temperature (40–60 °C), so scaling is slower
  • For high-hardness water projects, prefer low-pressure lamps (slower scaling)
  • Or, if medium-pressure lamps are chosen, intensify the cleaning

6. Criteria for Replacing Quartz Sleeves

Consider replacing a quartz sleeve when any of the following conditions occurs:

  1. Transmittance after cleaning is still below 80% of the initial value (abrasion or internal contamination)
  2. Severe scratches or pits on the surface (irreversible damage)
  3. Cracks or breakage (a safety hazard)
  4. Damaged sealing surfaces (the sleeve can no longer be sealed)
  5. Water has entered the sleeve (seal failure with internal scaling)
  6. Service life exceeds 5 years (normal water quality) or 3 years (poor water quality)
  7. UV intensity stays persistently low after lamp-related causes have been ruled out

When replacing a sleeve, replace the O-rings and seals at the same time.

7. Longkang Quartz Sleeve Configuration and Services

Quartz sleeve configuration for Longkang open-channel UV disinfection systems:

  1. Material: JGS2 UV-grade optical quartz glass, SiO2 ≥ 99.99%
  2. Transmittance: 254 nm transmittance ≥ 92% (above the national standard of ≥ 90%)
  3. Wall thickness: 1.5 mm (low-pressure lamps) / 2.0 mm (medium-pressure lamps), uniformity ±0.2 mm
  4. Surface: inner and outer surfaces polished to Ra ≤ 0.8 µm
  5. Testing: every sleeve undergoes a 254 nm transmittance test and a visual inspection before leaving the factory
  6. Optional: nano anti-scaling coating
  7. Supply: genuine original sleeves available long term, full range of sizes (outer diameter 25–35 mm, length 800–1600 mm)

Longkang services:

  1. Provide sleeve material certificates and transmittance test reports
  2. Guidance on sleeve cleaning and maintenance
  3. Supply of genuine original sleeves (prompt dispatch)
  4. On-site replacement guidance
  5. Transmittance sampling service
  6. Material evaluation for special water qualities
  7. 24-hour technical support
  8. Lifetime after-sales service

For projects located outside the region, support is still available as long as the drawings and parameters are aligned. Contact Longkang for sleeve selection and technical support.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong