Quartz Sleeve Transmittance Parameters

High-purity quartz sleeve of a UV sterilizer with 254 nm transmittance of at least 90 percent
Quartz sleeve transmittance determines the UV dose delivered to the water

The quartz sleeve is a key component of a UV sterilizer, and its transmittance directly affects disinfection performance. Longkang uses high-purity quartz sleeves to ensure efficient UV transmission. This article explains the transmittance parameters of quartz sleeves.

1. Importance of transmittance

1.1 What is transmittance

Transmittance is the percentage of light that passes through a material, equal to the ratio of transmitted light intensity to incident light intensity.

Formula: T = I_t / I_0 × 100%

  • T: transmittance (%)
  • I_t: transmitted light intensity
  • I_0: incident light intensity

1.2 Why transmittance matters

  • UV light from the lamp must pass through the quartz sleeve before it can reach the water
  • Low transmittance means the sleeve absorbs UV light and the disinfection dose drops
  • Transmittance of 90% means 90% of the UV light passes through and 10% is absorbed
  • Transmittance directly affects disinfection performance

1.3 Effects of declining transmittance

  • When transmittance falls from 90% to 70%, UV output drops by 22%
  • The disinfection dose falls accordingly
  • Incomplete sterilization may result
  • The sleeve needs cleaning or replacement

2. Quartz glass vs. ordinary glass transmittance

Material Transmittance at 254 nm Notes
High-purity quartz glass (JGS1) ≥90% Designed for UV disinfection
Ozone-filtering quartz glass (JGS2) ≥85% Blocks 185 nm, transmits 254 nm
Ordinary quartz glass (JGS3) ≥80% Slightly lower purity
Borosilicate glass (Pyrex) ≤30% Most UV light is absorbed
Ordinary soda-lime glass ≤10% Almost no UV transmission

Key conclusion: a quartz sleeve must be used. Ordinary glass has extremely low transmittance and cannot be used in a UV sterilizer.

3. Factors affecting transmittance

3.1 Material purity

  • The higher the silica content, the higher the transmittance
  • JGS1: SiO₂ ≥99.99%, transmittance ≥90%
  • JGS2: SiO₂ ≥99%, transmittance ≥85%
  • Impurities such as iron and aluminum absorb UV light and reduce transmittance

3.2 Hydroxyl content

  • Hydroxyl groups (OH⁻) absorb infrared light and have little effect at 254 nm
  • However, high hydroxyl content affects high-temperature performance
  • JGS1: hydroxyl content below 1 ppm (synthetic quartz)
  • JGS2: hydroxyl content 100–200 ppm (fused quartz)

3.3 Wall thickness

  • The thicker the wall, the longer the optical path and the more light is absorbed
  • Transmittance declines slightly as wall thickness increases
  • 1.5 mm wall thickness: transmittance ≥90%
  • 2.0 mm wall thickness: transmittance ≥88%
  • 2.5 mm wall thickness: transmittance ≥85%
  • Longkang uses a standard 1.5 mm wall thickness, balancing transmission and strength

3.4 Surface quality

  • A rough surface increases scattering and lowers transmittance
  • Surface polishing to Ra ≤0.8 µm gives high transmittance
  • Surface scratches and pits reduce transmittance
  • Longkang sleeves are surface-polished for high transmittance

3.5 Temperature

  • Transmittance declines slightly as temperature rises
  • 25 °C: baseline transmittance
  • 100 °C: transmittance falls by about 2–3%
  • At normal water temperatures of 5–45 °C, the effect is negligible

3.6 Wavelength

  • Transmittance varies with wavelength
  • 254 nm: highest transmittance (near the transmission peak of quartz glass)
  • 185 nm: lower transmittance (blocked by JGS2)
  • Visible light: transmittance above 95%
  • Longkang focuses on transmittance at 254 nm

4. Quartz sleeve transmittance standards

Item Specification
Material High-purity quartz glass (JGS1/JGS2)
Silica content ≥99%
Transmittance at 254 nm ≥90% (JGS1) / ≥85% (JGS2)
Transmittance at 185 nm ≥80% (JGS1) / ≤10% (JGS2, ozone-filtering)
Visible light transmittance ≥93%
Wall thickness 1.5–2.5 mm
Wall thickness uniformity ±0.3 mm
Surface roughness Ra ≤0.8 µm
Appearance No bubbles, no stones, no scratches
Temperature resistance 1,100 °C (instantaneous)
Pressure resistance ≥1.0 MPa

5. Transmittance testing methods

5.1 UV spectrophotometer method

  • Use a UV-visible spectrophotometer
  • Set the wavelength to 254 nm
  • Measure the transmittance of a sleeve sample
  • Accurate and reliable
  • Used for factory testing

5.2 UV intensity meter method

  • Use a UV intensity meter with a 254 nm probe
  • Measure UV intensity without the sleeve (I_0)
  • Measure UV intensity with the sleeve (I_t)
  • Transmittance = I_t / I_0 × 100%
  • Used for on-site testing

5.3 On-site monitoring

  • Equipped with an online UV intensity monitor
  • Real-time monitoring of UV intensity
  • A drop in intensity indicates sleeve fouling or lamp ageing
  • Indirectly monitors changes in transmittance

6. Transmittance changes in service

6.1 New sleeve

  • Transmittance ≥90%
  • Clean surface with no fouling

6.2 After three months

  • Good water quality: transmittance ≥85% (slight fouling)
  • Poor water quality: transmittance may fall to 70% (severe fouling)
  • Cleaning is required

6.3 After six months

  • Good water quality: transmittance ≥80%
  • Poor water quality: transmittance may fall below 60%
  • Cleaning is mandatory

6.4 After cleaning

  • Transmittance recovers to ≥85%
  • Severe fouling may not be fully recoverable

6.5 Ageing (3–5 years)

  • Quartz glass ages and transmittance declines
  • Replacement is recommended when transmittance falls below 80%

7. Measures to maintain transmittance

7.1 Regular cleaning

  • Good water quality: clean every 3–6 months
  • Poor water quality: clean every 1–2 months
  • Use citric acid or a dedicated cleaning agent
  • Transmittance recovers after cleaning

7.2 Automatic cleaning device

  • Fitted with an electric cleaning brush for timed automatic cleaning
  • Clean once a day
  • Keep transmittance stable
  • Reduce manual maintenance

7.3 Water pretreatment

  • High-iron water: iron removal pretreatment
  • High-hardness water: softening treatment
  • High-turbidity water: filtration pretreatment
  • Reduce fouling

7.4 Use high-quality sleeves

  • High-purity quartz glass
  • Surface polishing
  • High transmittance
  • Longkang supplies high-quality sleeves as standard

8. Relationship between transmittance and disinfection dose

Disinfection dose is proportional to transmittance: D_actual = D_theoretical × τ

  • D_actual: actual dose
  • D_theoretical: theoretical dose (with a new sleeve)
  • τ: sleeve transmittance

Example:

  • Theoretical dose 60 mJ/cm²
  • New sleeve with 90% transmittance: actual dose 54 mJ/cm²
  • Fouled sleeve with 70% transmittance: actual dose 42 mJ/cm² (close to the national standard lower limit)
  • Severely fouled sleeve with 50% transmittance: actual dose 30 mJ/cm² (below the standard)

Conclusion: sleeve transmittance must be maintained at ≥80%; otherwise the disinfection dose falls below the standard.

9. Longkang quartz sleeve commitments

  1. Use high-purity quartz glass (JGS2 ozone-filtering type)
  2. Transmittance at 254 nm ≥90%
  3. Wall thickness 1.5 mm, uniform to ±0.3 mm
  4. Surface polishing, Ra ≤0.8 µm
  5. Every sleeve is tested for transmittance before leaving the factory
  6. A transmittance test report is included
  7. Long-term supply of original manufacturer sleeves
  8. An optional automatic cleaning device to maintain transmittance

For selection support and quartz sleeve specifications, contact Longkang.