UV Sterilizer Piping Connection Methods

UV sterilizer piping connection options including flange, threaded and clamp fittings
Comparing piping connection methods for UV sterilizer installation

Piping connection is an important part of UV sterilizer installation. The choice of connection method directly affects installation efficiency, sealing performance and maintenance convenience. Longkang UV sterilizers support a variety of piping connection methods to suit different project requirements. This article explains each connection method in detail.

1. Overview of connection methods

Common piping connection methods for UV sterilizers:

  1. Flange connection (large diameter, DN50 and above)
  2. Threaded connection (small diameter, DN50 and below)
  3. Union connection (easy to disassemble)
  4. Clamp connection (quick-fit type, sanitary grade)
  5. Welded connection (permanent connection)

Select the appropriate connection method according to the unit diameter, pipe material and maintenance requirements.

2. Flange connection

2.1 Application scope

  • Large-diameter units: DN50 and above
  • Medium and large projects: secondary water supply, water plants
  • Higher pressure: ≥0.6 MPa
  • Requires frequent disassembly for inspection

2.2 Flange standards

  • National standard: GB/T 9119 (plate-type slip-on welded steel pipe flanges)
  • Pressure ratings: PN10 (1.0 MPa), PN16 (1.6 MPa)
  • Sealing face: raised face (RF)
  • Material: 304 stainless steel (same as the unit)

2.3 Flange specifications

Diameter Flange outer diameter Number of bolt holes Bolt specification Bolt hole diameter
DN50 160 mm 4 M16 18 mm
DN65 185 mm 4 M16 18 mm
DN80 200 mm 8 M16 18 mm
DN100 220 mm 8 M16 18 mm
DN125 250 mm 8 M16 18 mm
DN150 285 mm 8 M20 22 mm
DN200 340 mm 12 M20 22 mm

2.4 Gasket selection

  • Rubber gasket: ordinary water, temperature resistance ≤80°C
  • EPDM (ethylene propylene diene monomer): drinking water, temperature resistance ≤120°C
  • PTFE (polytetrafluoroethylene) gasket: corrosion resistant, temperature resistance ≤200°C
  • Spiral wound gasket: high temperature and high pressure
  • For drinking water use EPDM or food-grade rubber

2.5 Installation steps

  1. Clean the flange sealing face (no oil, no scratches)
  2. Place the gasket (centred, not skewed)
  3. Align the flanges (bolt holes aligned)
  4. Insert the bolts (in diagonal sequence)
  5. Tighten the nuts (evenly in diagonal order, in 2 to 3 passes)
  6. Torque: M16 = 60 N·m, M20 = 100 N·m
  7. Check the gasket extrusion (even all around)

2.6 Precautions

  • The flange sealing face must have no scratches or pits
  • Do not reuse gaskets (replace after disassembly)
  • Tighten bolts evenly in diagonal order to prevent skewing
  • Keep the flange and pipe coaxial (misalignment creates stress)
  • Provide independent pipe support; do not load the flange

3. Threaded connection

3.1 Application scope

  • Small-diameter units: DN15 to DN50
  • Small projects: household and small commercial applications
  • Lower pressure: ≤0.6 MPa
  • Limited installation space

3.2 Thread standards

  • Pipe thread: GB/T 7306 (55° sealing pipe threads)
  • Types: taper internal thread (Rc) / taper external thread (R)
  • Common sizes: 1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″, 2″
  • Thread angle: 55°

3.3 Thread specifications

Diameter Thread specification Threads per inch Major diameter
DN15 1/2″ 14 20.955 mm
DN20 3/4″ 14 26.441 mm
DN25 1″ 11 33.249 mm
DN32 1-1/4″ 11 41.910 mm
DN40 1-1/2″ 11 47.803 mm
DN50 2″ 11 59.614 mm

3.4 Sealing materials

  • PTFE tape (polytetrafluoroethylene): most common, wrap clockwise 5 to 8 turns
  • Thread sealant (liquid PTFE): applied to the thread, seals after curing
  • Hemp and lead oil: traditional method, gradually being phased out
  • Use food-grade sealing materials for drinking water

3.5 Installation steps

  1. Clean the threads (no oil, no impurities)
  2. Wrap PTFE tape on the external thread (clockwise, starting from the end, 5 to 8 turns)
  3. Hand-threaded engagement (2 to 3 turns, confirm no cross-threading)
  4. Tighten with a pipe wrench (a further 2 to 3 turns)
  5. Do not overtighten (to prevent thread cracks)
  6. Clean off any excess PTFE tape

3.6 Precautions

  • Wrap PTFE tape clockwise (the tightening direction); counterclockwise wrapping will loosen
  • Do not wrap too much (it may extrude into the pipe and contaminate the water)
  • Threads must have no damage or corrosion
  • Use moderate tightening force (too tight causes cracks, too loose causes leaks)
  • Use stainless steel fittings with stainless steel threads (to prevent electrochemical corrosion)

4. Union connection

4.1 Application scope

  • Applications requiring frequent disassembly for inspection
  • Small-diameter units: DN15 to DN50
  • Projects with frequent equipment maintenance

4.2 Union structure

  • A union consists of three parts: male end, female end and locking nut
  • The male end connects to the unit, the female end to the pipe
  • The locking nut compresses the male and female ends together
  • A gasket is placed on the sealing face

4.3 Materials

  • Stainless steel union: 304 or 316L
  • Copper union: nickel-plated copper
  • Plastic union: UPVC (low pressure)
  • For drinking water use stainless steel or food-grade copper

4.4 Installation steps

  1. Weld or thread the male end to the unit
  2. Weld or thread the female end to the pipe
  3. Place a gasket on the sealing face of the male and female ends
  4. Bring the male and female ends together
  5. Tighten the locking nut
  6. Check the seal

4.5 Advantages

  • Easy to disassemble for inspection (simply unscrew the nut to separate)
  • No need to rotate the pipe
  • Reliable sealing
  • Reusable (replace the gasket)

5. Clamp connection (quick-fit type)

5.1 Application scope

  • Applications with high sanitary requirements
  • Food, beverage and pharmaceutical industries
  • Requirement for quick disassembly and cleaning
  • Medium and low pressure: ≤0.6 MPa

5.2 Clamp structure

  • Quick-fit ferrules (one on the unit, one on the pipe)
  • Silicone sealing ring (between the two ferrules)
  • Clamp (locks the two ferrules together)
  • Locked by a handle or bolts

5.3 Standards

  • ISO 2852 (sanitary quick-fit standard)
  • 3A standard (US sanitary standard)
  • Ferrule diameter: according to the pipe size
  • Material: 304 or 316L stainless steel

5.4 Installation steps

  1. Clean the ferrule sealing faces
  2. Place the silicone sealing ring (centred)
  3. Bring the two ferrules together
  4. Slip the clamp over the ferrules
  5. Lock the handle or bolts
  6. Check the seal

5.5 Advantages

  • Quick disassembly (no tools needed, just move the handle)
  • Sanitary grade (no dead corners, easy to clean)
  • Reliable sealing
  • Suitable for frequent cleaning and disinfection

6. Welded connection

6.1 Application scope

  • Permanent connection, no disassembly required
  • Large-diameter pipes
  • Higher pressure
  • Stainless steel piping systems

6.2 Welding methods

  • TIG (argon arc) welding: most common, good weld quality
  • Manual arc welding: for large diameter and thick walls
  • Welding material: stainless steel wire of the same material
  • Shielding gas: 99.99% argon

6.3 Installation steps

  1. Bevel the pipe (V-groove, angle 60° to 70°)
  2. Fit up the joint (gap 1 to 2 mm, misalignment ≤0.5 mm)
  3. Tack weld (3 to 4 points, symmetrical)
  4. Root pass (TIG welding, single-sided welding with double-sided formation)
  5. Fill passes (multiple layers and passes)
  6. Cap pass (weld reinforcement 0.5 to 1.5 mm)
  7. Post-weld cleaning (slag and oxidation colour)
  8. Pickling and passivation (optional, improves corrosion resistance)
  9. Hydrostatic pressure test

6.4 Precautions

  • Welders must be certified
  • Welding procedure qualification must be passed
  • Non-destructive testing of welds (if required)
  • Hydrostatic pressure test after welding
  • Permanent connection; equipment inspection requires cutting (direct welding of the unit is not recommended)

7. Selection of connection method

Connection method Applicable diameter Pressure Disassembly Sealing Cost Application
Flange connection DN50 and above High Good Good Medium Medium and large projects
Threaded connection DN50 and below Medium Medium Medium Low Small projects
Union connection DN50 and below Medium Good Good Medium Frequent inspection
Clamp connection DN15 to DN100 Medium-low Very good Good High Sanitary, food applications
Welded connection All diameters High None Very good Medium Permanent piping

8. Longkang configuration

  1. Standard configuration: flange connection (DN50 and above), threaded connection (DN50 and below)
  2. Optional configuration: union and clamp connections
  3. Flange standard: GB/T 9119, PN10/PN16
  4. Material: 304 stainless steel (standard), 316L (optional)
  5. Gasket: food-grade EPDM (standard)
  6. Connection drawings and installation guidance provided
  7. Connection methods can be customized to project requirements

Contact Longkang for selection support and connection drawings tailored to your project.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong