UV Intensity Monitoring Parameters

UV intensity monitor sensor installed inside a Longkang UV sterilizer chamber
Online UV intensity monitoring on a Longkang UV sterilizer

UV intensity monitoring is an important means of safeguarding disinfection performance. It tracks UV output in real time and promptly detects problems such as lamp ageing and quartz sleeve fouling. Longkang UV sterilizers can be fitted with an optional online UV intensity monitor. This article explains the parameters of UV intensity monitoring.

1. Why UV intensity monitoring is needed

1.1 Disinfection performance is invisible

  • UV light cannot be seen or touched
  • Disinfection performance cannot be observed directly
  • It can only be judged indirectly through water quality testing
  • Water quality testing takes a long time and cannot reflect conditions in real time

1.2 UV output decays over time

  • Lamp ageing: power gradually declines
  • Sleeve fouling: transmittance falls
  • Power fluctuations: affect output
  • These changes are invisible to the naked eye

1.3 Problems are detected in time

  • Alarm when intensity falls to the threshold
  • Replace lamps or clean sleeves promptly
  • Avoid insufficient disinfection dose
  • Safeguard water quality safety

1.4 Operation records

  • Record changes in UV intensity
  • Trace disinfection performance
  • Provide a basis for maintenance
  • Meet health supervision requirements

2. How a UV intensity monitor works

2.1 Sensor

  • Uses a UV photodiode
  • Sensitive to the 254 nm wavelength
  • Converts the UV light signal into an electrical signal
  • The electrical signal is proportional to UV intensity

2.2 Signal processing

  • Amplification: amplifies the weak electrical signal
  • Filtering: removes interference
  • A/D conversion: converts the analogue signal to a digital signal
  • Calculation: converts the reading into a UV intensity value (mW/cm² or percent)

2.3 Display and alarm

  • Displays real-time UV intensity
  • Displays lamp operating time
  • Alarms when intensity falls below the threshold
  • Alarm outputs (audible/visual, relay, remote)

3. Monitor technical parameters

3.1 Measurement parameters

  • Measurement wavelength: 254 nm (peak response)
  • Measurement range: 0 to 10 mW/cm² (or 0 to 100 percent)
  • Measurement accuracy: ±5 percent
  • Resolution: 0.01 mW/cm² (or 1 percent)
  • Response time: <1 s

3.2 Sensor parameters

  • Sensor type: UV photodiode
  • Effective photosensitive area: approx. 1 cm²
  • Spectral response range: 220 to 280 nm
  • Peak wavelength: 254 nm
  • Cosine correction: yes (angular response correction)
  • Operating temperature: -10 to 60 °C
  • Waterproof rating: IP68 (submersible type)

3.3 Display parameters

  • Display type: LCD or LED digital display
  • Displayed content: UV intensity (percent or mW/cm²), lamp time, alarm status
  • Display accuracy: 1 percent
  • Backlight: yes (optional)

3.4 Alarm parameters

  • Alarm threshold: settable (default 70 percent)
  • Alarm method: audible and visual alarm, relay output
  • Relay capacity: 250 VAC / 5 A
  • Alarm delay: settable (0 to 60 s, to prevent false alarms)
  • Historical alarm records: queryable

3.5 Output parameters

  • Analogue output: 4 to 20 mA (corresponding to 0 to 100 percent)
  • Digital output: RS485 (Modbus protocol)
  • Relay outputs: alarm, operation, fault
  • Can be connected to a PLC or remote monitoring system

3.6 Electrical parameters

  • Supply voltage: 220 VAC ±10 percent or 24 VDC
  • Power consumption: <5 W
  • Insulation resistance: ≥2 MΩ
  • Waterproof rating: IP65 (display unit)
  • Operating temperature: -10 to 50 °C

4. Sensor installation position

4.1 Installation principles

  • Install inside the chamber, in the UV irradiation zone
  • Point the sensor surface towards the lamp
  • Do not interfere with the water flow
  • Allow easy replacement and calibration

4.2 Typical positions

  • Chamber side wall: the sensor is embedded in the wall with its photosensitive face towards the lamp
  • Chamber end: the sensor is mounted at the end, facing the lamp
  • Quartz sleeve protection: a quartz sleeve encloses the sensor to keep out water

4.3 Precautions

  • The sensor must not be obstructed
  • The sensor surface must not become fouled (clean it regularly)
  • The distance between sensor and lamp is fixed (calibration reference)
  • The sensor cable must be sealed and waterproof

5. Relationship between intensity monitoring and dose

5.1 Intensity and dose

Dose = intensity × time

  • Intensity monitoring reflects UV output in real time
  • When flow is stable, dose is proportional to intensity
  • As intensity falls, dose falls accordingly

5.2 Alarm threshold setting

  • A new lamp gives 100 percent intensity
  • Intensity at the end of lamp life is approx. 70 percent
  • The alarm threshold defaults to 70 percent
  • At 70 percent, replace the lamp
  • It can also be set to 80 percent for stricter water quality requirements

5.3 Intensity and germicidal performance

  • 100 percent intensity: sufficient dose, thorough disinfection
  • 80 percent intensity: slightly lower dose, still compliant
  • 70 percent intensity: dose close to the lower limit, replace the lamp
  • <70 percent intensity: dose may fail to meet the standard, replacement is required

6. Monitor calibration

6.1 Why calibration is needed

  • Sensor sensitivity drifts after a period of use
  • Fouling of the sensor surface affects readings
  • Regular calibration is needed to keep measurements accurate

6.2 Calibration interval

  • Generally once a year
  • After replacing a lamp
  • After cleaning the sensor
  • When readings are abnormal

6.3 Calibration method

  • Use a calibrated standard UV intensity meter as the reference
  • Measure the UV intensity at the same position at the same time
  • Adjust the monitor reading to match the reference
  • Record the calibration data

6.4 Longkang service

  • Calibration guidance is provided
  • Calibration service is available (on site or at the factory)
  • A calibration certificate is provided
  • Sensors are supplied long term

7. Common monitor faults

7.1 Zero reading

  • Cause: sensor damaged, cable disconnected, lamp not lit
  • Action: check the lamp, check the cable, replace the sensor

7.2 Low reading

  • Cause: fouled sensor surface, lamp ageing, sensor drift
  • Action: clean the sensor, replace the lamp, calibrate

7.3 Large reading fluctuation

  • Cause: poor contact, power fluctuation, sensor fault
  • Action: check the wiring, stabilise the power supply, replace the sensor

7.4 False alarms

  • Cause: alarm threshold set too low, alarm delay too short
  • Action: adjust the threshold, increase the delay

8. Longkang monitor configuration

  1. Online UV intensity monitor (optional)
  2. Dedicated 254 nm sensor, accuracy ±5 percent
  3. LCD display of real-time intensity and lamp time
  4. Audible and visual alarm (intensity below 70 percent)
  5. Relay output (for an external alarm)
  6. RS485 communication (for remote monitoring)
  7. Sensor rated IP68, suitable for submersible installation
  8. Calibration service and technical support provided

For selection support and project-specific advice on UV intensity monitoring, contact Longkang.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong