Low-Pressure UV Lamp Performance Parameters

Low-pressure UV lamp with a 253.7 nm germicidal wavelength used in a UV sterilizer
Low-pressure UV lamp performance parameters

Low-pressure UV lamps are the most commonly used lamp type in UV sterilizers, offering high electrical-to-optical efficiency, long service life and high germicidal efficiency at a single wavelength. Longkang UV sterilizers are equipped with high-quality low-pressure UV lamps as standard. This article explains the performance parameters of low-pressure UV lamps.

1. How low-pressure UV lamps work

A low-pressure UV lamp is a low-pressure mercury-vapour discharge lamp filled with low-pressure mercury vapour (0.1 to 1 Pa) and an inert gas (argon). When powered, electrons bombard mercury atoms and excite them; as the atoms return from the excited state to the ground state they emit ultraviolet light, mainly at 253.7 nm (the wavelength with the highest germicidal efficiency) and 185 nm (the wavelength that generates ozone).

Ozone-free low-pressure lamps are used for drinking water disinfection; they transmit only 253.7 nm and block 185 nm.

2. Specification parameters of low-pressure UV lamps

Power Lamp length Lamp diameter Service life Suitable treatment capacity
14 W 330 mm 15 mm 8000 h 0.5 m³/h
28 W 550 mm 15 mm 8000 h 1 m³/h
40 W 840 mm 16 mm 9000 h 2 m³/h
80 W 1500 mm 19 mm 10000 h 5 m³/h
120 W 1500 mm 19 mm 10000 h 7.5 m³/h
160 W 1500 mm 19 mm 12000 h 10 m³/h
320 W 1500 mm 23 mm 12000 h 20 m³/h

3. Electro-optical performance parameters

3.1 UV output

  • UV output power at 253.7 nm
  • Electrical-to-optical conversion efficiency: 35 to 40 percent
  • 40 W lamp: UV output of approximately 14 to 16 W
  • 80 W lamp: UV output of approximately 28 to 32 W
  • 160 W lamp: UV output of approximately 56 to 64 W

3.2 Start-up characteristics

  • Instant on, no warm-up required
  • Start-up time: <1 s
  • Can be switched on and off frequently (without affecting service life)
  • Equipped with an electronic ballast for reliable starting

3.3 Operating voltage

  • Lamp operating voltage: 100 to 200 V (depending on power)
  • Connected to a 220 V/380 V supply via a ballast
  • Operates normally with voltage fluctuations of ±10 percent

3.4 Operating current

  • 14 W: 0.17 A
  • 40 W: 0.42 A
  • 80 W: 0.80 A
  • 160 W: 1.50 A
  • 320 W: 2.80 A

4. Spectral characteristics

4.1 Main wavelength

  • 253.7 nm (germicidal wavelength)
  • Accounts for more than 90 percent of the UV output
  • The wavelength with the highest germicidal efficiency

4.2 Other wavelengths

  • 185 nm (ozone wavelength): blocked by ozone-free lamps
  • Visible light: a small amount (blue-violet)
  • Infrared: a small amount (heat)

4.3 Ozone-free type

  • A lamp coating blocks 185 nm
  • No ozone is generated
  • Suitable for drinking water and indoor environments
  • Ambient ozone concentration ≤0.1 mg/m³

4.4 Ozone-generating type

  • Transmits 185 nm
  • Generates ozone
  • Ozone can assist disinfection, decolourisation and odour removal
  • Suitable for wastewater and exhaust gas treatment
  • Generally not used for drinking water

5. Service life characteristics

5.1 Rated service life

  • Standard low-pressure lamps: 8000 hours
  • High-quality low-pressure lamps: 10000 to 12000 hours
  • Service life is the time until UV output decays to 70 percent
  • It is not the time until the lamp burns out completely

5.2 Power decay

  • New lamp: 100 percent output
  • 4000 hours: approximately 90 percent
  • 8000 hours: approximately 75 percent
  • 12000 hours: approximately 70 percent (end of life)
  • Replacement is recommended when output decays to 70 percent

5.3 Factors affecting service life

  • Switching cycles: frequent switching slightly affects service life (little effect for low-pressure lamps)
  • Operating temperature: too high or too low affects service life
  • Power quality: voltage fluctuations affect service life
  • Ballast matching: a poor match shortens service life

6. Physical characteristics

6.1 Lamp materials

  • Quartz glass tube (transmits UV)
  • Tungsten filament electrodes
  • Mercury or amalgam (low-pressure mercury lamps use liquid mercury or amalgam)
  • Inert gas (argon)

6.2 Lamp shape

  • Straight tube (most common)
  • U-shaped (special applications)
  • Spiral (special applications)
  • Longkang uses straight-tube lamps

6.3 Lamp base

  • Ceramic base (high-temperature resistant)
  • Four-pin or single-pin base
  • Waterproof lamp holder
  • Connected to the ballast

7. Advantages of low-pressure lamps

  1. High electrical-to-optical efficiency: 35 to 40 percent, with low operating cost
  2. Single-wavelength germicidal action: 253.7 nm has the highest germicidal efficiency
  3. Long service life: 8000 to 12000 hours
  4. Instant on: no warm-up required
  5. Frequent switching: does not affect service life
  6. Wide power range: 14 W to 320 W
  7. Low price: less expensive than medium-pressure lamps
  8. Safe replacement: low power makes replacement safe

8. Limitations of low-pressure lamps

  1. Low power per lamp: high flow rates require many lamps
  2. Large chamber volume: multi-lamp designs need a larger chamber
  3. Limited effectiveness against Cryptosporidium: requires a high dose
  4. Cannot decompose organic matter: no advanced oxidation effect
  5. Temperature sensitive: high water temperature affects output

9. Longkang’s low-pressure lamp configuration

  1. High-quality domestic low-pressure lamps supplied as standard (cost-effective)
  2. Imported low-pressure lamps available as an option (Philips, Heraeus, with longer service life)
  3. Ozone-free type (253.7 nm), suitable for drinking water
  4. Equipped with a high-efficiency electronic ballast
  5. Equipped with a lamp operating-hour counter
  6. Equipped with a UV intensity monitor
  7. Long-term supply of original-manufacturer lamps
  8. Lamp replacement guidance provided

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong