Medium-Pressure UV Lamp Performance Parameters Explained

Medium-pressure UV lamp continuous spectrum and performance parameter chart for open-channel disinfection
Medium-pressure UV lamp performance parameters at a glance

Medium-pressure (MP) lamps are another important lamp type for open-channel UV disinfection systems, and are widely used in large and medium-sized wastewater treatment plants, water reclamation plants, and projects with low UV transmittance (UVT). They offer high power per lamp, multi-wavelength disinfection, fewer modules, and a compact footprint. This article sets out the performance parameters, characteristics, and applications of medium-pressure UV lamps, presenting the conclusions first and then the supporting rationale.

1. Working Principle of Medium-Pressure Lamps

1.1 Light generation principle

  • The lamp is filled with medium-pressure mercury vapour (approx. 10^5–10^6 Pa, i.e. 0.1–1 MPa) and other metal halides
  • When energized, the electrodes emit electrons, which are accelerated in a strong electric field
  • Electrons collide with mercury atoms and metal ions, exciting them to multiple high energy levels
  • As the excited species fall back from multiple high energy levels to lower levels, several spectral lines are emitted
  • A continuous UV spectrum from 200 to 400 nm is formed, together with visible light and infrared radiation

1.2 Differences from low-pressure lamps

  • Mercury vapour pressure: more than 1,000 times higher than in low-pressure lamps
  • Spectrum: MP lamps produce a multi-wavelength continuous spectrum; low-pressure lamps emit a single wavelength
  • Power: 1–10 kW per MP lamp; a maximum of 0.32 kW for low-pressure lamps
  • Wall temperature: 80–120 °C for MP lamps, 40–60 °C for low-pressure lamps
  • Electrical-to-UV efficiency: 15%–20% for MP lamps, 35%–40% for low-pressure lamps
  • Start-up: MP lamps require 1–3 minutes of warm-up; low-pressure lamps start instantly

1.3 Spectral characteristics

  • Continuous UV spectrum from 200 to 400 nm
  • Principal emission lines: 254 nm, 265 nm, 280 nm, 297 nm, 313 nm, 334 nm, 365 nm, and others
  • 254 nm: peak DNA absorption, germicidal action
  • 260–280 nm: absorbed by proteins and nucleic acids; effective against oocysts/cysts and viruses
  • 300–365 nm: long-wave UV supporting disinfection and photochemical reactions
  • Synergistic multi-wavelength inactivation, more effective against Cryptosporidium/Giardia and resistant viruses
  • Visible light and infrared radiation are also produced (wasted energy, hence low electrical-to-UV efficiency)

2. Core Performance Parameters

2.1 Power parameters

Parameter Value range Notes
Rated power 1 kW, 3 kW, 5 kW, 7 kW, 10 kW Common ratings
Operating voltage 300–800 V Voltage across the lamp
Operating current 3–15 A Varies with power rating
Ignition voltage 2,000–5,000 V High voltage required to trigger ignition
Input power tolerance ±5% Deviation of actual power from the nominal value
Power adjustment range 40%–100% Dimmable models

2.2 UV output parameters

Parameter Value range Notes
Total UV output (200–400 nm) 150–2,000 W Total UV radiation output
UV output at 254 nm 100–1,000 W Germicidally effective UV (approx. 50%–60% of total UV)
Electrical-to-UV efficiency 15%–20% Total UV output / input power
254 nm share 10%–15% 254 nm output / input power
Initial output tolerance ±10% Output variation within the same production batch
End-of-life output ≥70% of initial output Basis for the lamp life definition

2.3 Lamp life parameters

Parameter Value range Notes
Rated life 6,000–8,000 h Time until output decays to 70%
Effect of switching cycles Each on/off cycle reduces life by approx. 5–10 h Frequent switching significantly shortens life
Optimum operating temperature 80–120 °C (wall temperature) Output falls if the temperature is too low
Warm-up time 1–3 min Time from ignition to full power
End-of-life criterion Output <70% of initial value or failure to ignite Replacement criterion

2.4 Dimensional parameters

Parameter Value range Notes
Lamp outer diameter 23–29 mm T9/T11 formats
Lamp length 300–1,200 mm Varies with power rating
Electrode length 20–40 mm Electrode sections at both ends
Arc length Total length − 2 × electrode length Effective light-emitting section

2.5 Electrical characteristics

Parameter Value range Notes
Power factor ≥0.95 (with electronic ballast) Grid-side power factor
Total harmonic distortion (THD) ≤20% Current harmonics
Warm-up time 1–3 min Time from ignition to full power
Starting behaviour Requires warm-up; not suitable for frequent switching Frequent switching shortens life
Dimming Supported (40%–100% power adjustment) Energy-saving operation
Ignition method High-voltage pulse ignition Requires a dedicated igniter

3. Performance Characteristics of Medium-Pressure Lamps

3.1 Advantages

(1) High power per lamp

  • 1–10 kW per lamp, 3–30 times that of low-pressure high-output (LPHO) lamps
  • Fewer lamps required for high-flow projects
  • Fewer modules, shorter channels, smaller footprint
  • More economical for high-flow projects (>5,000 m³/h)

(2) Multi-wavelength disinfection

  • Continuous 200–400 nm spectrum with synergistic multi-wavelength inactivation
  • Effective inactivation of Cryptosporidium oocysts and Giardia cysts, even at relatively low doses
  • Broader inactivation spectrum for resistant viruses such as adenovirus
  • Multiple wavelengths cause combined DNA and protein damage, reducing the likelihood of photoreactivation
  • Suited to high-standard reclaimed water and stringent discharge projects

(3) Fewer modules

  • For the same treatment capacity, MP systems use only 1/3 to 1/5 as many modules as LPHO systems
  • Shorter channels, smaller footprint
  • Less installation and maintenance work
  • Simpler cabling and control systems
  • Well suited to retrofit projects with limited space

(4) Dimming capability

  • MP lamps support power adjustment from 40% to 100%
  • Power can be adjusted automatically according to flow and water quality
  • Power is reduced at low flow or with good water quality, saving 30%–50% in energy
  • Extends lamp life, since output decays more slowly at reduced power
  • Suited to projects with widely varying flow

(5) Insensitivity to water temperature

  • Wall temperature of 80–120 °C, far above the water temperature
  • Changes in water temperature have little effect on lamp output
  • Continues to operate normally in low-temperature environments (below 5 °C)
  • Stable operation through northern winters

3.2 Disadvantages

(1) Low electrical-to-UV efficiency

  • Efficiency of 15%–20%, well below LPHO lamps (35%–40%)
  • Higher power consumption for the same UV output
  • Higher operating cost due to electricity consumption
  • Useful 254 nm output is only 10%–15% of input power

(2) Shorter lamp life

  • Life of 6,000–8,000 h, 30%–50% shorter than LPHO lamps
  • Short replacement interval (every 8–11 months under 24-hour daily operation)
  • High lamp cost (several thousand RMB per lamp, more than 10 times that of a low-pressure lamp)
  • High lamp replacement expense

(3) Slow start-up

  • Requires 1–3 minutes of warm-up to reach full power
  • Cannot be switched frequently (each on/off cycle reduces life by 5–10 h)
  • Not suited to grouped control or duty rotation
  • Warm-up must be repeated after a power outage
  • Standby modules must be kept preheated, which consumes power

(4) High operating temperature

  • Wall temperature of 80–120 °C
  • High thermal stress on quartz sleeves; high-temperature-resistant sleeves required
  • Ballasts generate substantial heat and require effective cooling
  • High temperatures can accelerate seal ageing
  • Burn risk on contact, so guarding is required

(5) High cost

  • High cost per lamp (RMB 3,000–10,000 per lamp)
  • Expensive ballasts, since high-voltage ignition and dimming are required
  • Higher capital investment
  • High replacement cost

(6) Ozone and visible light generation

  • 185 nm UV can generate ozone, so ozone-blocking quartz sleeves are required
  • Visible light and infrared radiation are produced (wasted energy)
  • Lit lamps emit intense light (guarding required; avoid direct viewing)

4. Application of Medium-Pressure Lamps in Open-Channel UV Systems

4.1 Suitable project scale

  • Large and medium projects with capacity >2,000 m³/h
  • Large municipal wastewater treatment plants (above 100,000 t/d)
  • Large water reclamation plants
  • Low-quality water projects with UVT <65%
  • Stringent effluent requirements (reclaimed water, special discharge limits)
  • Projects requiring Cryptosporidium/Giardia inactivation
  • Retrofit projects with limited space
  • Projects with large flow variations that benefit from dimming

4.2 Module configuration

  • 2–4 lamps per module
  • Number of modules determined by flow capacity and UV dose
  • Typically 4–10 modules, including N+1 redundancy
  • Modules can be lifted out as complete assemblies for maintenance
  • High module power (6–40 kW per module)

4.3 Ballast configuration

  • One dedicated electronic ballast per lamp, with high-voltage ignition and dimming
  • Ballasts installed in cabinets above the channel
  • IP65-rated ballast enclosures with effective heat dissipation
  • Power factor ≥0.95
  • Supports 0–10 V or RS485 dimming signals

4.4 Control strategy

  • Automatic PLC control
  • Automatic dimming, with power adjusted to flow / UVT
  • Online UV intensity monitoring
  • Remote monitoring via SCADA/DCS
  • Not suited to frequent grouped control because of the long warm-up
  • Standby modules kept preheated for rapid bring-online

5. Selection Guidelines for Medium-Pressure Lamps

5.1 Power selection

  • Medium projects (2,000–5,000 m³/h): select 3–5 kW
  • Large projects (5,000–10,000 m³/h): select 5–7 kW
  • Very large projects (>10,000 m³/h): select 7–10 kW
  • Higher power means fewer lamps but a higher price per lamp
  • 5 kW is the most common rating and offers the best cost/performance ratio

5.2 Brand selection

  • Imported brands: Heraeus, Trojan, Aquafine, Philips
    • Advantages: long life (8,000 h), stable output, reliable quality, good dimming performance
    • Disadvantages: high price (RMB 5,000–15,000 per lamp), long lead times
  • Domestic brands: Xuelaite, Youhui, Guangpu
    • Advantages: low price (RMB 2,000–5,000 per lamp), fast delivery, convenient after-sales service
    • Disadvantages: slightly shorter life (6,000 h), average dimming performance
  • Longkang supplies high-quality domestic MP lamps as standard, with imported lamps available as an option

5.3 Dimming function

  • Dimmable models are recommended for critical projects
  • Dimming range: 40%–100%
  • Dimming interface: 0–10 V analogue signal or RS485 digital signal
  • Dimming can save 30%–50% in energy when flow varies widely
  • Running at reduced power extends lamp life

5.4 Quartz sleeve matching

  • MP lamp outer diameter 23–29 mm
  • Use sleeves with 26–32 mm inner diameter (29–35 mm outer diameter, 1.5–2.0 mm wall thickness)
  • Because MP lamps run hot, a 2.0 mm wall is recommended for better thermal-stress resistance
  • JGS2 ozone-blocking fused-silica quartz sleeves are mandatory, blocking 185 nm to prevent ozone formation

6. Maintenance of Medium-Pressure Lamps

6.1 Lamp replacement

  • Replace by lamp life, when output decays to 70%
  • Or replace by operating hours (6,000–8,000 h)
  • Allow the lamp to cool before replacement (wait 15 minutes after switch-off)
  • Replace the O-rings at the same time
  • Allow 1–3 minutes of warm-up after replacement
  • See Article 37 for the detailed procedure

6.2 Sleeve cleaning

  • High lamp temperatures can cause heavier sleeve fouling, as heat promotes mineral deposition
  • Automatic cleaning runs 1–4 times per day
  • Manual cleaning every 1–3 months, depending on water quality
  • Take care with high temperatures and allow the unit to cool before cleaning
  • See Article 38 for the detailed procedure

6.3 UV intensity monitoring

  • UV intensity monitoring for each lamp, or for each module
  • A steady decline in intensity may indicate lamp ageing or sleeve fouling
  • MP lamps decay faster than low-pressure lamps and require close monitoring
  • An alarm or automatic power increase is triggered when intensity falls below the setpoint

6.4 Electrical inspection

  • Ballasts generate substantial heat; verify that cooling is effective
  • Check ballast operating temperature (≤70 °C)
  • Check that the high-voltage ignition circuit is functioning
  • Check terminals for looseness, since high currents cause heating
  • Ensure reliable grounding

6.5 Dimming system maintenance

  • Calibrate the dimming signal regularly
  • Check that the flow and UVT sensors are functioning
  • Verify that the dimming logic is correct
  • Record the energy savings achieved

7. Longkang Medium-Pressure Lamp Configuration

Medium-pressure lamp configuration of Longkang open-channel UV disinfection systems:

  1. Lamps: High-quality domestic MP lamps as standard; imported lamps (Heraeus / Trojan) optional
  2. Power: 1 kW / 3 kW / 5 kW / 7 kW / 10 kW options
  3. Life: 6,000–8,000 h
  4. Electrical-to-UV efficiency: ≥15%
  5. Spectrum: Continuous 200–400 nm spectrum
  6. Dimming: 40%–100% power adjustment supported (optional)
  7. Ballast: Dedicated electronic ballast with high-voltage ignition, power factor ≥0.95, IP65
  8. Control: Automatic PLC control, automatic dimming, remote monitoring
  9. Supply: Long-term supply of original lamps, with a full range of ratings
  10. Replacement: Replacement guidance and on-site replacement service

8. Quick Comparison: Low-Pressure High-Output vs Medium-Pressure Lamps

Comparison item Low-pressure high-output (LPHO) lamp Medium-pressure (MP) lamp
Power per lamp 150–320 W 1–10 kW
Spectrum Single wavelength 253.7 nm Multi-wavelength 200–400 nm
Electrical-to-UV efficiency 35%–40% 15%–20%
Lamp life 8,000–12,000 h 6,000–8,000 h
Start-up Instant on Warm-up 1–3 min
Wall temperature 40–60 °C 80–120 °C
Dimming Supported on some models Supported (40%–100%)
Cryptosporidium inactivation Moderate (high dose required) Good (multi-wavelength)
Applicable flow ≤5,000 m³/h >2,000 m³/h
Operating cost Low High
Footprint Large (more modules) Small (fewer modules)

9. Longkang Services

  1. Medium-pressure lamp selection consulting
  2. Provision of lamp technical data and test reports
  3. Dimming system design and commissioning
  4. Guidance on lamp replacement and maintenance
  5. Supply of original lamps with prompt delivery
  6. On-site lamp replacement service
  7. UV intensity testing and calibration
  8. Lamp life assessment
  9. Energy-saving performance assessment
  10. 24-hour technical support

For the same unit, upgrading the chamber material from 304 to 316L stainless steel can add several years of service life — this is not a place to cut costs.

Contact Longkang for selection support.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong