Medium-Pressure UV Lamp Performance Parameters Explained

Medium-pressure (MP) lamps are another important lamp type for open-channel UV disinfection systems, and are widely used in large and medium-sized wastewater treatment plants, water reclamation plants, and projects with low UV transmittance (UVT). They offer high power per lamp, multi-wavelength disinfection, fewer modules, and a compact footprint. This article sets out the performance parameters, characteristics, and applications of medium-pressure UV lamps, presenting the conclusions first and then the supporting rationale.
1. Working Principle of Medium-Pressure Lamps
1.1 Light generation principle
- The lamp is filled with medium-pressure mercury vapour (approx. 10^5–10^6 Pa, i.e. 0.1–1 MPa) and other metal halides
- When energized, the electrodes emit electrons, which are accelerated in a strong electric field
- Electrons collide with mercury atoms and metal ions, exciting them to multiple high energy levels
- As the excited species fall back from multiple high energy levels to lower levels, several spectral lines are emitted
- A continuous UV spectrum from 200 to 400 nm is formed, together with visible light and infrared radiation
1.2 Differences from low-pressure lamps
- Mercury vapour pressure: more than 1,000 times higher than in low-pressure lamps
- Spectrum: MP lamps produce a multi-wavelength continuous spectrum; low-pressure lamps emit a single wavelength
- Power: 1–10 kW per MP lamp; a maximum of 0.32 kW for low-pressure lamps
- Wall temperature: 80–120 °C for MP lamps, 40–60 °C for low-pressure lamps
- Electrical-to-UV efficiency: 15%–20% for MP lamps, 35%–40% for low-pressure lamps
- Start-up: MP lamps require 1–3 minutes of warm-up; low-pressure lamps start instantly
1.3 Spectral characteristics
- Continuous UV spectrum from 200 to 400 nm
- Principal emission lines: 254 nm, 265 nm, 280 nm, 297 nm, 313 nm, 334 nm, 365 nm, and others
- 254 nm: peak DNA absorption, germicidal action
- 260–280 nm: absorbed by proteins and nucleic acids; effective against oocysts/cysts and viruses
- 300–365 nm: long-wave UV supporting disinfection and photochemical reactions
- Synergistic multi-wavelength inactivation, more effective against Cryptosporidium/Giardia and resistant viruses
- Visible light and infrared radiation are also produced (wasted energy, hence low electrical-to-UV efficiency)
2. Core Performance Parameters
2.1 Power parameters
| Parameter | Value range | Notes |
|---|---|---|
| Rated power | 1 kW, 3 kW, 5 kW, 7 kW, 10 kW | Common ratings |
| Operating voltage | 300–800 V | Voltage across the lamp |
| Operating current | 3–15 A | Varies with power rating |
| Ignition voltage | 2,000–5,000 V | High voltage required to trigger ignition |
| Input power tolerance | ±5% | Deviation of actual power from the nominal value |
| Power adjustment range | 40%–100% | Dimmable models |
2.2 UV output parameters
| Parameter | Value range | Notes |
|---|---|---|
| Total UV output (200–400 nm) | 150–2,000 W | Total UV radiation output |
| UV output at 254 nm | 100–1,000 W | Germicidally effective UV (approx. 50%–60% of total UV) |
| Electrical-to-UV efficiency | 15%–20% | Total UV output / input power |
| 254 nm share | 10%–15% | 254 nm output / input power |
| Initial output tolerance | ±10% | Output variation within the same production batch |
| End-of-life output | ≥70% of initial output | Basis for the lamp life definition |
2.3 Lamp life parameters
| Parameter | Value range | Notes |
|---|---|---|
| Rated life | 6,000–8,000 h | Time until output decays to 70% |
| Effect of switching cycles | Each on/off cycle reduces life by approx. 5–10 h | Frequent switching significantly shortens life |
| Optimum operating temperature | 80–120 °C (wall temperature) | Output falls if the temperature is too low |
| Warm-up time | 1–3 min | Time from ignition to full power |
| End-of-life criterion | Output <70% of initial value or failure to ignite | Replacement criterion |
2.4 Dimensional parameters
| Parameter | Value range | Notes |
|---|---|---|
| Lamp outer diameter | 23–29 mm | T9/T11 formats |
| Lamp length | 300–1,200 mm | Varies with power rating |
| Electrode length | 20–40 mm | Electrode sections at both ends |
| Arc length | Total length − 2 × electrode length | Effective light-emitting section |
2.5 Electrical characteristics
| Parameter | Value range | Notes |
|---|---|---|
| Power factor | ≥0.95 (with electronic ballast) | Grid-side power factor |
| Total harmonic distortion (THD) | ≤20% | Current harmonics |
| Warm-up time | 1–3 min | Time from ignition to full power |
| Starting behaviour | Requires warm-up; not suitable for frequent switching | Frequent switching shortens life |
| Dimming | Supported (40%–100% power adjustment) | Energy-saving operation |
| Ignition method | High-voltage pulse ignition | Requires a dedicated igniter |
3. Performance Characteristics of Medium-Pressure Lamps
3.1 Advantages
(1) High power per lamp
- 1–10 kW per lamp, 3–30 times that of low-pressure high-output (LPHO) lamps
- Fewer lamps required for high-flow projects
- Fewer modules, shorter channels, smaller footprint
- More economical for high-flow projects (>5,000 m³/h)
(2) Multi-wavelength disinfection
- Continuous 200–400 nm spectrum with synergistic multi-wavelength inactivation
- Effective inactivation of Cryptosporidium oocysts and Giardia cysts, even at relatively low doses
- Broader inactivation spectrum for resistant viruses such as adenovirus
- Multiple wavelengths cause combined DNA and protein damage, reducing the likelihood of photoreactivation
- Suited to high-standard reclaimed water and stringent discharge projects
(3) Fewer modules
- For the same treatment capacity, MP systems use only 1/3 to 1/5 as many modules as LPHO systems
- Shorter channels, smaller footprint
- Less installation and maintenance work
- Simpler cabling and control systems
- Well suited to retrofit projects with limited space
(4) Dimming capability
- MP lamps support power adjustment from 40% to 100%
- Power can be adjusted automatically according to flow and water quality
- Power is reduced at low flow or with good water quality, saving 30%–50% in energy
- Extends lamp life, since output decays more slowly at reduced power
- Suited to projects with widely varying flow
(5) Insensitivity to water temperature
- Wall temperature of 80–120 °C, far above the water temperature
- Changes in water temperature have little effect on lamp output
- Continues to operate normally in low-temperature environments (below 5 °C)
- Stable operation through northern winters
3.2 Disadvantages
(1) Low electrical-to-UV efficiency
- Efficiency of 15%–20%, well below LPHO lamps (35%–40%)
- Higher power consumption for the same UV output
- Higher operating cost due to electricity consumption
- Useful 254 nm output is only 10%–15% of input power
(2) Shorter lamp life
- Life of 6,000–8,000 h, 30%–50% shorter than LPHO lamps
- Short replacement interval (every 8–11 months under 24-hour daily operation)
- High lamp cost (several thousand RMB per lamp, more than 10 times that of a low-pressure lamp)
- High lamp replacement expense
(3) Slow start-up
- Requires 1–3 minutes of warm-up to reach full power
- Cannot be switched frequently (each on/off cycle reduces life by 5–10 h)
- Not suited to grouped control or duty rotation
- Warm-up must be repeated after a power outage
- Standby modules must be kept preheated, which consumes power
(4) High operating temperature
- Wall temperature of 80–120 °C
- High thermal stress on quartz sleeves; high-temperature-resistant sleeves required
- Ballasts generate substantial heat and require effective cooling
- High temperatures can accelerate seal ageing
- Burn risk on contact, so guarding is required
(5) High cost
- High cost per lamp (RMB 3,000–10,000 per lamp)
- Expensive ballasts, since high-voltage ignition and dimming are required
- Higher capital investment
- High replacement cost
(6) Ozone and visible light generation
- 185 nm UV can generate ozone, so ozone-blocking quartz sleeves are required
- Visible light and infrared radiation are produced (wasted energy)
- Lit lamps emit intense light (guarding required; avoid direct viewing)
4. Application of Medium-Pressure Lamps in Open-Channel UV Systems
4.1 Suitable project scale
- Large and medium projects with capacity >2,000 m³/h
- Large municipal wastewater treatment plants (above 100,000 t/d)
- Large water reclamation plants
- Low-quality water projects with UVT <65%
- Stringent effluent requirements (reclaimed water, special discharge limits)
- Projects requiring Cryptosporidium/Giardia inactivation
- Retrofit projects with limited space
- Projects with large flow variations that benefit from dimming
4.2 Module configuration
- 2–4 lamps per module
- Number of modules determined by flow capacity and UV dose
- Typically 4–10 modules, including N+1 redundancy
- Modules can be lifted out as complete assemblies for maintenance
- High module power (6–40 kW per module)
4.3 Ballast configuration
- One dedicated electronic ballast per lamp, with high-voltage ignition and dimming
- Ballasts installed in cabinets above the channel
- IP65-rated ballast enclosures with effective heat dissipation
- Power factor ≥0.95
- Supports 0–10 V or RS485 dimming signals
4.4 Control strategy
- Automatic PLC control
- Automatic dimming, with power adjusted to flow / UVT
- Online UV intensity monitoring
- Remote monitoring via SCADA/DCS
- Not suited to frequent grouped control because of the long warm-up
- Standby modules kept preheated for rapid bring-online
5. Selection Guidelines for Medium-Pressure Lamps
5.1 Power selection
- Medium projects (2,000–5,000 m³/h): select 3–5 kW
- Large projects (5,000–10,000 m³/h): select 5–7 kW
- Very large projects (>10,000 m³/h): select 7–10 kW
- Higher power means fewer lamps but a higher price per lamp
- 5 kW is the most common rating and offers the best cost/performance ratio
5.2 Brand selection
- Imported brands: Heraeus, Trojan, Aquafine, Philips
- Advantages: long life (8,000 h), stable output, reliable quality, good dimming performance
- Disadvantages: high price (RMB 5,000–15,000 per lamp), long lead times
- Domestic brands: Xuelaite, Youhui, Guangpu
- Advantages: low price (RMB 2,000–5,000 per lamp), fast delivery, convenient after-sales service
- Disadvantages: slightly shorter life (6,000 h), average dimming performance
- Longkang supplies high-quality domestic MP lamps as standard, with imported lamps available as an option
5.3 Dimming function
- Dimmable models are recommended for critical projects
- Dimming range: 40%–100%
- Dimming interface: 0–10 V analogue signal or RS485 digital signal
- Dimming can save 30%–50% in energy when flow varies widely
- Running at reduced power extends lamp life
5.4 Quartz sleeve matching
- MP lamp outer diameter 23–29 mm
- Use sleeves with 26–32 mm inner diameter (29–35 mm outer diameter, 1.5–2.0 mm wall thickness)
- Because MP lamps run hot, a 2.0 mm wall is recommended for better thermal-stress resistance
- JGS2 ozone-blocking fused-silica quartz sleeves are mandatory, blocking 185 nm to prevent ozone formation
6. Maintenance of Medium-Pressure Lamps
6.1 Lamp replacement
- Replace by lamp life, when output decays to 70%
- Or replace by operating hours (6,000–8,000 h)
- Allow the lamp to cool before replacement (wait 15 minutes after switch-off)
- Replace the O-rings at the same time
- Allow 1–3 minutes of warm-up after replacement
- See Article 37 for the detailed procedure
6.2 Sleeve cleaning
- High lamp temperatures can cause heavier sleeve fouling, as heat promotes mineral deposition
- Automatic cleaning runs 1–4 times per day
- Manual cleaning every 1–3 months, depending on water quality
- Take care with high temperatures and allow the unit to cool before cleaning
- See Article 38 for the detailed procedure
6.3 UV intensity monitoring
- UV intensity monitoring for each lamp, or for each module
- A steady decline in intensity may indicate lamp ageing or sleeve fouling
- MP lamps decay faster than low-pressure lamps and require close monitoring
- An alarm or automatic power increase is triggered when intensity falls below the setpoint
6.4 Electrical inspection
- Ballasts generate substantial heat; verify that cooling is effective
- Check ballast operating temperature (≤70 °C)
- Check that the high-voltage ignition circuit is functioning
- Check terminals for looseness, since high currents cause heating
- Ensure reliable grounding
6.5 Dimming system maintenance
- Calibrate the dimming signal regularly
- Check that the flow and UVT sensors are functioning
- Verify that the dimming logic is correct
- Record the energy savings achieved
7. Longkang Medium-Pressure Lamp Configuration
Medium-pressure lamp configuration of Longkang open-channel UV disinfection systems:
- Lamps: High-quality domestic MP lamps as standard; imported lamps (Heraeus / Trojan) optional
- Power: 1 kW / 3 kW / 5 kW / 7 kW / 10 kW options
- Life: 6,000–8,000 h
- Electrical-to-UV efficiency: ≥15%
- Spectrum: Continuous 200–400 nm spectrum
- Dimming: 40%–100% power adjustment supported (optional)
- Ballast: Dedicated electronic ballast with high-voltage ignition, power factor ≥0.95, IP65
- Control: Automatic PLC control, automatic dimming, remote monitoring
- Supply: Long-term supply of original lamps, with a full range of ratings
- Replacement: Replacement guidance and on-site replacement service
8. Quick Comparison: Low-Pressure High-Output vs Medium-Pressure Lamps
| Comparison item | Low-pressure high-output (LPHO) lamp | Medium-pressure (MP) lamp |
|---|---|---|
| Power per lamp | 150–320 W | 1–10 kW |
| Spectrum | Single wavelength 253.7 nm | Multi-wavelength 200–400 nm |
| Electrical-to-UV efficiency | 35%–40% | 15%–20% |
| Lamp life | 8,000–12,000 h | 6,000–8,000 h |
| Start-up | Instant on | Warm-up 1–3 min |
| Wall temperature | 40–60 °C | 80–120 °C |
| Dimming | Supported on some models | Supported (40%–100%) |
| Cryptosporidium inactivation | Moderate (high dose required) | Good (multi-wavelength) |
| Applicable flow | ≤5,000 m³/h | >2,000 m³/h |
| Operating cost | Low | High |
| Footprint | Large (more modules) | Small (fewer modules) |
9. Longkang Services
- Medium-pressure lamp selection consulting
- Provision of lamp technical data and test reports
- Dimming system design and commissioning
- Guidance on lamp replacement and maintenance
- Supply of original lamps with prompt delivery
- On-site lamp replacement service
- UV intensity testing and calibration
- Lamp life assessment
- Energy-saving performance assessment
- 24-hour technical support
For the same unit, upgrading the chamber material from 304 to 316L stainless steel can add several years of service life — this is not a place to cut costs.
Contact Longkang for selection support.