Medium-Pressure UV Lamp Performance Parameters

Medium-pressure UV lamps are high-power UV lamps offering multi-wavelength output, high power per lamp and a broad germicidal spectrum, making them suitable for disinfection applications with high flow rates and complex water quality. Longkang offers medium-pressure UV sterilizer options. This article explains the performance parameters of medium-pressure UV lamps.
1. How medium-pressure UV lamps work
A medium-pressure UV lamp is a medium-pressure mercury-vapour discharge lamp filled with medium-pressure mercury vapour (100 to 10000 Pa). When powered, mercury atoms are excited and emit multi-wavelength ultraviolet light (a continuous spectrum from 200 to 400 nm), including the 253.7 nm germicidal wavelength and other wavelengths.
Unlike the single wavelength of low-pressure lamps, medium-pressure lamps emit a continuous spectrum with a broader germicidal range that is effective against a wide variety of microorganisms.
2. Specification parameters of medium-pressure UV lamps
| Power | Lamp length | Lamp diameter | Service life | Suitable treatment capacity |
|---|---|---|---|---|
| 1 kW | 300 mm | 20 mm | 6000 h | 10 to 20 m³/h |
| 3 kW | 500 mm | 22 mm | 6000 h | 30 to 60 m³/h |
| 5 kW | 600 mm | 25 mm | 7000 h | 50 to 100 m³/h |
| 7 kW | 700 mm | 25 mm | 7000 h | 70 to 140 m³/h |
| 10 kW | 800 mm | 28 mm | 8000 h | 100 to 200 m³/h |
3. Electro-optical performance parameters
3.1 UV output
- Multi-wavelength output from 200 to 400 nm
- Electrical-to-optical conversion efficiency: 15 to 20 percent
- 1 kW lamp: UV output of approximately 150 to 200 W
- 5 kW lamp: UV output of approximately 750 to 1000 W
- High total UV output
3.2 Start-up characteristics
- Requires warm-up: 1 to 3 minutes to reach full power
- Cannot be switched frequently (affects service life)
- Must cool for 5 to 10 minutes before restarting after shutdown
- Equipped with a dedicated medium-pressure ballast
3.3 Operating voltage
- Lamp operating voltage: 500 to 2000 V
- Connected to a 380 V three-phase supply via a ballast
- High starting voltage
3.4 Operating current
- 1 kW: approximately 3 A
- 3 kW: approximately 8 A
- 5 kW: approximately 13 A
- 10 kW: approximately 25 A
4. Spectral characteristics
4.1 Multi-wavelength output
- Continuous spectrum from 200 to 400 nm
- Includes:
- 253.7 nm (germicidal wavelength)
- 265 nm (nucleic acid absorption peak)
- 280 nm (protein absorption)
- 300 to 365 nm (long-wave UV)
- Multi-wavelength synergistic germicidal action
4.2 Broad germicidal spectrum
- Effective against bacteria, viruses, protozoa and mould
- Different wavelengths act on different parts of microorganisms
- More thorough disinfection
4.3 Advanced oxidation
- The 185 nm wavelength can generate ozone
- The 254 nm wavelength can excite hydrogen peroxide to produce hydroxyl radicals
- Can decompose organic matter in water (micropollutants)
- Achieves disinfection and degradation at the same time
4.4 Ozone-free and ozone-generating types
- Ozone-free type: a coating blocks 185 nm
- Ozone-generating type: transmits 185 nm and generates ozone
- Use the ozone-free type for drinking water
5. Service life characteristics
5.1 Rated service life
- Medium-pressure lamps: 6000 to 8000 hours
- Shorter than low-pressure lamps
- Service life is the time until UV output decays to 70 percent
5.2 Power decay
- New lamp: 100 percent output
- 3000 hours: approximately 85 percent
- 6000 hours: approximately 75 percent
- 8000 hours: approximately 70 percent (end of life)
5.3 Factors affecting service life
- Switching cycles: frequent switching seriously affects service life (about one hour of life lost per switch)
- Operating temperature: excessive heat affects service life
- Power quality: voltage fluctuations affect service life
- Cooling: water temperature that is too low or too high has an effect
6. Physical characteristics
6.1 Lamp materials
- Quartz glass tube (high-temperature resistant)
- Thoriated tungsten electrodes (high-temperature resistant)
- Liquid mercury
- Inert gas
6.2 Operating temperature
- Lamp surface temperature: 600 to 900 °C
- Chamber water temperature: 5 to 45 °C
- Large temperature difference requires a quartz sleeve for insulation
6.3 Lamp shape
- Straight tube (most common)
- High-power lamps are longer and thicker
6.4 Lamp base
- Ceramic base (high-temperature resistant)
- Single-pin or double-pin
- Waterproof lamp holder
7. Advantages of medium-pressure lamps
- High power per lamp: 1 to 10 kW, so high flow rates need only a few lamps
- Broad germicidal spectrum: multiple wavelengths, effective against a wide range of microorganisms
- Compact chamber: fewer lamps mean a smaller chamber
- Advanced oxidation: can decompose organic matter
- Effective against Cryptosporidium: through multi-wavelength synergy
- Suitable for high flow rates: clear advantages above 100 m³/h
- Suitable for complex water quality: multiple wavelengths adapt to different water conditions
8. Limitations of medium-pressure lamps
- Low electrical-to-optical efficiency: 15 to 20 percent, with high power consumption
- Short service life: 6000 to 8000 hours
- Requires warm-up: 1 to 3 minutes, not instant on
- Cannot be switched frequently: affects service life
- High price: lamps and ballasts are expensive
- High operating temperature: cooling must be considered
- Hazardous replacement: high power means replacement should be done by qualified personnel
9. Medium-pressure vs low-pressure selection
| Item | Low-pressure lamp | Medium-pressure lamp |
|---|---|---|
| Power per lamp | 14 to 320 W | 1 to 10 kW |
| Wavelength | Single wavelength 253.7 nm | Multi-wavelength 200 to 400 nm |
| Electrical efficiency | 35 to 40 percent | 15 to 20 percent |
| Service life | 8000 to 12000 h | 6000 to 8000 h |
| Start-up | Instant on | 1 to 3 min warm-up |
| Frequent switching | Yes | No |
| Suitable flow | ≤50 m³/h | >50 m³/h |
| Suitable water quality | Good | Complex |
| Equipment cost | Low | High |
| Operating cost | Low | High |
| Chamber volume | Larger | Smaller |
10. Longkang’s medium-pressure lamp configuration
- Imported medium-pressure lamps available as an option (Heraeus, Aquafine)
- Ozone-free type, suitable for drinking water
- Equipped with a dedicated medium-pressure electronic ballast
- Equipped with a lamp operating-hour counter
- Equipped with UV intensity monitoring
- Equipped with water temperature monitoring (to prevent overheating)
- Professional installation and replacement service
- Suitable for high-flow, complex-water-quality projects