Quartz Sleeve Cleaning Methods for UV Sterilizers

Technician wiping a UV sterilizer quartz sleeve with a soft cloth and citric acid solution
Regular quartz sleeve cleaning restores UV transmittance and disinfection performance

The quartz sleeve is a critical component of a UV sterilizer. During operation, mineral scale builds up on its surface, reducing UV transmittance and compromising disinfection performance. Regular cleaning of the quartz sleeve is an essential part of routine maintenance. This article explains quartz sleeve cleaning methods and the key precautions in detail.

1. Why quartz sleeves need cleaning

1.1 Sleeve fouling

  • Minerals in the water such as calcium, magnesium and iron deposit on the sleeve surface
  • Forming limescale or iron deposits
  • Scaling reduces UV transmittance
  • Lower transmittance leads to an insufficient UV dose

1.2 Fouling rate

  • Good-quality water (tap water): slow fouling, noticeable after 3-6 months
  • Poor-quality water (groundwater, high-hardness water): fast fouling, noticeable after 1-2 months
  • High-iron water: even faster fouling, noticeable after 1 month
  • Higher water temperature accelerates fouling

1.3 Impact of fouling

  • Transmittance drops from 90% to 70%, and UV output falls by 22%
  • The delivered disinfection dose falls accordingly
  • Potentially resulting in incomplete inactivation
  • Treated water failing to meet quality standards

1.4 Benefits of cleaning

  • After cleaning, transmittance recovers to above 85%
  • Disinfection performance is restored
  • Sleeve service life is extended
  • Water safety is maintained

2. Cleaning intervals

2.1 By water quality

  • High-quality tap water (turbidity <1 NTU, hardness <150 mg/L): clean every 3-6 months
  • Standard tap water: clean every 2-3 months
  • Groundwater or high-hardness water: clean every 1-2 months
  • High-iron water: clean every month
  • Seawater or high-salinity water: clean every month

2.2 By UV intensity

  • Clean when UV intensity falls to 80% of its initial value
  • Intensity continues to decline
  • Intensity recovers after cleaning

2.3 By visual inspection

  • Inspect the sleeve surface regularly
  • Clean when scale is visible to the naked eye
  • Clean when the sleeve surface appears whitish or yellowish

2.4 Automatic cleaning systems

  • Units fitted with an automatic cleaning system: one automatic cleaning cycle per day
  • No manual cleaning required
  • Transmittance remains stable

3. Preparation before cleaning

3.1 Safety preparation

  • Disconnect the power supply (confirm the power is off)
  • Close the inlet and outlet valves
  • Open the drain valve and fully drain the chamber
  • Open the air-vent valve
  • Allow the unit to cool down

3.2 Tools and materials

  • Gloves: acid-resistant gloves (for cleaning) and lint-free gloves (for installation)
  • Lint-free cloth or soft sponge
  • Citric acid or a dedicated cleaning agent
  • Plastic bucket (for mixing the cleaning solution)
  • Wrench (for the lamp-holder lock nut)
  • Clean water
  • Waste bags

3.3 Choosing a cleaning agent

  • Citric acid: 10%-20% aqueous solution, food grade, safe
  • Dedicated UV quartz-sleeve cleaner: prepare according to the instructions
  • Oxalic acid: 5%-10% aqueous solution (effective but toxic; observe safety precautions)
  • Hydrochloric acid: not recommended (highly corrosive, damages the sleeve)
  • Recommended: citric acid (safe and effective)

3.4 Precautions

  • Do not use steel wool or stiff brushes (they scratch the sleeve surface)
  • Do not use strong acids (hydrochloric or sulfuric acid, which damage the sleeve)
  • Do not use organic solvents (acetone and alcohol can degrease but are not used for descaling)
  • Do not scrape with a blade (it scratches the sleeve)
  • Wipe with a soft cloth or sponge

4. Cleaning procedure (sleeve removed)

4.1 Power off, isolate water and drain

  1. Disconnect the power supply
  2. Close the inlet and outlet valves
  3. Open the drain and air-vent valves
  4. Fully drain the chamber
  5. Allow the unit to cool

4.2 Remove the UV lamps

  1. Disconnect the lamp-head wiring
  2. Loosen the lamp-head lock nut
  3. Gently pull out the lamp
  4. Place used lamps in a safe location (or replace them)
  5. Remove multiple lamps one by one

4.3 Remove the quartz sleeve

  1. Loosen the lock nuts on the seal seats at both ends
  2. Gently pull out the quartz sleeve (withdraw it from one end)
  3. Note: the sleeve is fragile; handle with care
  4. Remove the O-rings (check whether replacement is needed)
  5. Remove multiple sleeves one by one

4.4 Prepare the cleaning solution

  1. Add warm water (40-50°C) to the plastic bucket
  2. Add citric acid to make a 10%-20% aqueous solution
  3. Stir until fully dissolved
  4. Do not let the water temperature exceed 60°C (to prevent thermal-stress cracking of the sleeve)

4.5 Soak the sleeve

  1. Place the quartz sleeve into the cleaning solution
  2. Submerge it completely
  3. Soak for 15-30 minutes (depending on the degree of fouling)
  4. For heavy fouling, extend soaking to 1 hour
  5. Turn the sleeve during soaking for uniform contact

4.6 Wipe the sleeve

  1. Put on acid-resistant gloves
  2. Dip a lint-free cloth or soft sponge in the cleaning solution
  3. Gently wipe the inner and outer walls of the sleeve
  4. Focus on the scaled areas
  5. Do not apply excessive force (to avoid breakage)
  6. Do not scrape with hard objects

4.7 Rinse with clean water

  1. Remove the sleeve
  2. Rinse the inner and outer walls with clean water
  3. Rinse until no cleaning-agent residue remains (neutral pH)
  4. Dry with a lint-free cloth
  5. Inspect the sleeve surface: smooth, free of scale and scratches

4.8 Inspect the sleeve

  1. Visual inspection: no cracks or damage
  2. Transmittance check: hold it to a light source and confirm transparency
  3. Sealing-surface check: no scratches
  4. Replace damaged sleeves
  5. Replace aged O-rings

4.9 Reinstallation

  1. Put on lint-free gloves
  2. Fit the O-rings (apply a small amount of silicone grease)
  3. Insert the sleeve into the chamber
  4. Install the seal seats at both ends
  5. Tighten the lock nuts
  6. Install the UV lamps
  7. Reconnect the wiring
  8. Close the drain and air-vent valves
  9. Refill with water and pressure-test
  10. Power on and run the unit

5. In-line cleaning (sleeve left in place)

5.1 When to use in-line cleaning

  • Large chambers where the sleeve is difficult to remove
  • Light fouling
  • Availability of a cleaning port

5.2 In-line cleaning procedure

  1. Power off, isolate water and drain
  2. Inject cleaning solution (10% citric acid) through the cleaning port
  3. Soak for 30-60 minutes
  4. Drain the cleaning solution
  5. Rinse with clean water
  6. Refill with water and resume operation
  • Note: the cleaning solution must not reach the lamps (they are separated by the sleeve); do not perform in-line cleaning if a sleeve is cracked

5.3 Automatic cleaning systems

  • Fitted with a motorized cleaning brush
  • The cleaning brush is mounted around the sleeve
  • A motor drives the brush back and forth along the sleeve
  • One automatic cleaning cycle per day
  • No manual intervention required
  • Transmittance remains stable

6. Verifying cleaning results

6.1 Visual verification

  • Sleeve surface is smooth and clean
  • No scale or whitish deposits
  • Clear and transparent

6.2 Transmittance verification

  • Measure with a UV intensity meter (radiometer)
  • Intensity should recover after cleaning
  • Compare with a new sleeve
  • Transmittance recovers to above 85%

6.3 Disinfection performance verification

  • Test the treated water quality
  • Total bacterial count and total coliforms
  • Must meet the applicable standards

6.4 Record keeping

  • Cleaning date
  • Cleaning agent and concentration
  • UV intensity before cleaning
  • UV intensity after cleaning
  • Personnel who performed the cleaning
  • Archive the record

7. Measures to prevent fouling

7.1 Water pretreatment

  • High-hardness water: softening
  • High-iron water: iron removal
  • High-turbidity water: filtration
  • Reduce scale-forming substances

7.2 Upstream filtration

  • Install a Y-type strainer
  • Remove suspended solids
  • Reduce deposition on the sleeve surface
  • Clean the strainer regularly

7.3 Automatic cleaning

  • Fit an automatic cleaning system
  • Automatic cleaning every day
  • Keep transmittance stable
  • Reduce manual maintenance

7.4 Use high-quality sleeves

  • High-purity quartz glass
  • Polished surface
  • Resistant to fouling
  • High UV transmittance

8. Common problems and troubleshooting

8.1 Poor transmittance recovery after cleaning

  • Cause: heavy fouling (silica or iron scale), incomplete cleaning, or an aged sleeve
  • Remedy: extend soaking time, use a dedicated cleaner, or replace the sleeve

8.2 Sleeve cracks after cleaning

  • Cause: excessive temperature difference (cold-water rinsing after hot cleaning), impact during installation, or over-tightening
  • Remedy: rinse with warm water, handle gently, and apply the correct torque

8.3 Scratches on the sleeve surface

  • Cause: scraping with hard objects or steel wool
  • Remedy: use only soft cloths and never hard objects; replace badly scratched sleeves

8.4 Frequent cleaning required

  • Cause: poor water quality (high hardness, high iron)
  • Remedy: apply water pretreatment and fit an automatic cleaning system

8.5 Corrosion from the cleaning solution

  • Cause: use of strong acid (hydrochloric acid)
  • Remedy: use citric acid instead of strong acids

9. Longkang cleaning support

Longkang provides the following support for quartz sleeve maintenance. Contact Longkang for selection and maintenance support tailored to your UV system.

  1. Detailed cleaning procedures and guidance
  2. Dedicated quartz-sleeve cleaning agents
  3. Remote technical support for cleaning and troubleshooting
  4. On-site cleaning service available where required
  5. Retrofit of automatic cleaning systems
  6. Quartz sleeve replacement service
  7. Post-cleaning verification and testing
  8. Maintenance training for operating staff
  9. Continuing technical support

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong